20
Participants
Start Date
November 16, 2020
Primary Completion Date
December 12, 2020
Study Completion Date
December 19, 2020
Hydrogel conventional toric lenses with -10° axis misalignment
The assessment visits interval is 1 week and completed exactly on day 14 after their first baseline visit. At each assessment visit, three different cylinder power were tested: 1) full cylinder power, 2) under-correction of cylinder power by 0.5 D, and 3) under-correction of cylinder power by 1.0 DC. Axis was also misaligned by -10° and +10° for each cylinder power alteration. The powers and axis assigned to the participants were randomized during every assessment visit. Baseline assessments and treatment allocations were masked to both patients and physician. All assessments were carried out on the day of observation and recorded on the subject evaluation sheet in accordance with the sample data, in which examinations results.
Hydrogel conventional toric lenses with +10° axis misalignment
The assessment visits interval is 1 week and completed exactly on day 14 after their first baseline visit. At each assessment visit, three different cylinder power were tested: 1) full cylinder power, 2) under-correction of cylinder power by 0.5 D, and 3) under-correction of cylinder power by 1.0 DC. Axis was also misaligned by -10° and +10° for each cylinder power alteration. The powers and axis assigned to the participants were randomized during every assessment visit. Baseline assessments and treatment allocations were masked to both patients and physician. All assessments were carried out on the day of observation and recorded on the subject evaluation sheet in accordance with the sample data, in which examinations results.
Hydrogel conventional toric lenses with undercorrection of 0.5 D
The assessment visits interval is 1 week and completed exactly on day 14 after their first baseline visit. At each assessment visit, three different cylinder power were tested: 1) full cylinder power, 2) under-correction of cylinder power by 0.5 D, and 3) under-correction of cylinder power by 1.0 DC. Axis was also misaligned by -10° and +10° for each cylinder power alteration. The powers and axis assigned to the participants were randomized during every assessment visit. Baseline assessments and treatment allocations were masked to both patients and physician. All assessments were carried out on the day of observation and recorded on the subject evaluation sheet in accordance with the sample data, in which examinations results.
Hydrogel conventional toric lenses with undercorrection of 1.0 D
The assessment visits interval is 1 week and completed exactly on day 14 after their first baseline visit. At each assessment visit, three different cylinder power were tested: 1) full cylinder power, 2) under-correction of cylinder power by 0.5 D, and 3) under-correction of cylinder power by 1.0 DC. Axis was also misaligned by -10° and +10° for each cylinder power alteration. The powers and axis assigned to the participants were randomized during every assessment visit. Baseline assessments and treatment allocations were masked to both patients and physician. All assessments were carried out on the day of observation and recorded on the subject evaluation sheet in accordance with the sample data, in which examinations results.
Department of Ophthalmology, Faculty of Medicine Universitas Indonesia Cipto Mangunkusumo Hospital, Indonesia, Jakarta
Indonesia University
OTHER