Efficacy of Ultrasound-Guided Genicular Nerve Radiofrequency Ablation Therapy

NARecruitingINTERVENTIONAL
Enrollment

66

Participants

Timeline

Start Date

April 15, 2025

Primary Completion Date

August 31, 2026

Study Completion Date

December 31, 2026

Conditions
Gonarthrosis
Interventions
PROCEDURE

2-point Radiofrequency Ablation

"For the radiofrequency ablation (RFA) procedure, a 10 cm long, 22 gauge RF cannula with a 10 mm active tip (Model SC-K, Top Neuropole, MPS Medical Product Service GmbH, Germany) will be used.~In order to increase the accuracy of the location determined by ultrasound, sensory stimulation will be applied at a frequency of 50 Hz and with a threshold value lower than 0.6 volts. In order to prevent the motor nerves from being affected, the absence of lower extremity muscle fasciculations in the relevant area will be confirmed with 2 volt stimulation at 2 Hz frequency. Patients in 2 nerve groups (SM and IM) will undergo 2-point RFA at 42°C using a 120-second pulse RFA generator (TOP Lesion Generator TLG-20, MPS Medical Product Service GmbH, Germany).~To address any discomfort that may occur after the procedure, a total of 2 cc of betamethasone (5 mg+2 mg/1 cc) and %2 lidocaine (1 cc) will be injected into the points where RFA is applied, after aspiration."

PROCEDURE

3-point Radiofrequency Ablation

Description: For the radiofrequency ablation (RFA) procedure, a 10 cm long, 22 gauge RF cannula with a 10 mm active tip (Model SC-K, Top Neuropole, MPS Medical Product Service GmbH, Germany) will be used. In order to increase the accuracy of the location determined by ultrasound, sensory stimulation will be applied at a frequency of 50 Hz and with a threshold value lower than 0.6 volts. In order to prevent the motor nerves from being affected, the absence of lower extremity muscle fasciculations in the relevant area will be confirmed with 2 volt stimulation at 2 Hz frequency. 3-point RFA will be applied to patients in 3 nerve groups (SM, SL and IM) using a generator (TOP Lesion Generator TLG-20, MPS Medical Product Service GmbH, Germany) in the form of 120-second pulse RFA at 42°C. To address any discomfort that may occur after the procedure, a total of 2 cc of betamethasone (5 mg+2 mg/1 cc) and %2 lidocaine (1cc) will be injected into the points where RFA is applied, after aspiration.

PROCEDURE

5-point Radiofrequency Ablation

Description: For the radiofrequency ablation (RFA) procedure, a 10 cm long, 22 gauge RF cannula with a 10 mm active tip (Model SC-K, Top Neuropole, MPS Medical Product Service GmbH, Germany) will be used. In order to increase the accuracy of the location determined by ultrasound, sensory stimulation will be applied at a frequency of 50 Hz and with a threshold value lower than 0.6 volts. In order to prevent the motor nerves from being affected, the absence of lower extremity muscle fasciculations in the relevant area will be confirmed with 2 volt stimulation at 2 Hz frequency. 5-point RFA will be applied to patients in 5 nerve groups (SM, SL and IM, recurrent fibular nerve-RFN, infrapatellar branch of saphenous nerve-IPBSN) via same generator in the form of 120-second pulse RFA at 42°C. To address any discomfort that may occur after the procedure, a total of 2cc of betamethasone (5mg+2mg/1cc) and %2 lidocaine (1cc) will be injected into the points where RFA is applied, after aspiration.