Comparison of the Post-operative Efficacy of Arch Bar With Single Plate and Two Plate Fixation in Mandibular Parasymphsis Fracture.

NACompletedINTERVENTIONAL
Enrollment

60

Participants

Timeline

Start Date

July 1, 2024

Primary Completion Date

June 30, 2025

Study Completion Date

June 30, 2025

Conditions
Mandible Fracture
Interventions
DEVICE

Titanium miniplates

Titanium miniplates are used for open reduction and internal fixation in mandible fractures according to Champy's principle of osteosynthesis

OTHER

Arch Bar

Arch bars are used for intermaxillary fixation in facial fractures as a mean of closed reduction.In this study arch bars placed in tension zone will be combined with single miniplate placed at inferior border of mandible and this modality efficacy will be compared with two miniplate group.

Trial Locations (1)

47070

Dental College Hitec Institute Of Medical Sciences Taxila Cantt, Taxila

All Listed Sponsors
lead

HITEC-Institute of Medical Sciences

OTHER