15
Participants
Start Date
February 10, 2025
Primary Completion Date
August 9, 2025
Study Completion Date
October 29, 2025
Electrical Muscle Stimulation
EMS will be applied bilaterally to the wrist flexor and elbow extensor muscles using a portable EMS stimulator (Compex Rehab 400, Medicompex SA, Ecublens, Switzerland). Four 2 mm thick, self-adhesive electrodes (5x5 cm) will be placed on the superficial aspect of each muscle group. The athletes will simultaneously receive EMS intervention with a pulse frequency of 75 Hz and a duration of 400 μs (19 seconds rest between pulses) during bench press and triceps pushdown exercises. Bench press and triceps push down exercises will be performed with 30% 1TM, 30-15-15-15 repetitions and thirty seconds rest between sets.
Blood Flow Restriction
The arterial occlusion pressures (AOP) of the athletes randomized to the experimental group will be obtained automatically with the digital LED display CAC device BFR Unit (Fit Cuffs BFR Unit, Denmark). The AOP pressure device BFR Unit (Fit Cuffs BFR Unit, Denmark) will be used to apply 50% occlusion pressure during exercise. Bench press and triceps push down exercises will be performed with 30% 1TM, 30-15-15-15 repetitions and thirty seconds rest between sets.
Low-Load Resistance Exercise
Bench press and triceps pushdown exercises will be performed with 30% 1RM, 30-15-15-15 repetitions and 30 seconds rest between sets.
Karabuk University, Karabük
Karabuk University
OTHER