60
Participants
Start Date
January 1, 2021
Primary Completion Date
August 1, 2021
Study Completion Date
September 1, 2021
Device: Volume-Controlled Ventilation (VCV)
Tidal volume: 8 mL/kg of ideal body weight Respiratory rate adjusted to maintain an end-tidal CO₂ (EtCO₂) level of 30-35 mmHg Inspiratory-expiratory ratio: 1:2 PEEP: 5 cmH₂O Mechanical ventilation was provided using a Datex-Ohmeda Avance Anesthesia Machine (GE Healthcare, USA) Measurements were taken at four predefined time points (T1-T4)
Device: Pressure-Controlled Ventilation (PCV)
Initial peak inspiratory pressure adjusted to deliver a tidal volume of 8 mL/kg of ideal body weight Respiratory rate adjusted to maintain an end-tidal CO₂ (EtCO₂) level of 30-35 mmHg Inspiratory-expiratory ratio: 1:2 PEEP: 5 cmH₂O Mechanical ventilation was provided using a Datex-Ohmeda Avance Anesthesia Machine (GE Healthcare, USA) Measurements were taken at four predefined time points (T1-T4)
Device: Pressure-Controlled Volume-Guaranteed Ventilation (PCV-VG)
Pressure-controlled mode with volume guarantee to maintain a tidal volume of 8 mL/kg of ideal body weight Respiratory rate adjusted to maintain an end-tidal CO₂ (EtCO₂) level of 30-35 mmHg Inspiratory-expiratory ratio: 1:2 PEEP: 5 cmH₂O Mechanical ventilation was provided using a Datex-Ohmeda Avance Anesthesia Machine (GE Healthcare, USA) Measurements were taken at four predefined time points (T1-T4)
Zeynep Kamil Maternity and Children's Training and Research Hospital, Istanbul
Dr. Lutfi Kirdar Kartal Training and Research Hospital
OTHER_GOV