Retention of Bioflx Crowns Compared to Zirconia Crowns on Primary Molars

NANot yet recruitingINTERVENTIONAL
Enrollment

50

Participants

Timeline

Start Date

June 30, 2025

Primary Completion Date

December 31, 2025

Study Completion Date

February 28, 2026

Conditions
Carious Primary Molars
Interventions
OTHER

(Group A: Preformed Bioflx crown)

"prepartion:1.The mesiodistal width of the tooth will be measured using calipers and a closely fitted crown will be selected based on the measurements.~2\. The tooth will be prepared similarly to stainless steel crowns (SSCs):~* Occlusal reduction of approximately 1-1.5 mm will be done using a diamond bur.Mesial and distal reduction of no more than 1 mm will be performed using a No. 169L diamond bur.Depending on the tooth anatomy, either no buccal and lingual reduction will be needed, or a minimal reduction will be done.~ 3.All sharp line angles and corners will be smoothed to ensure proper crown fit.~ 4.The crown will be checked for proper fit before cementation. It will be positioned to extend 1 mm below the gingival margin.~ 5.The crown will be cemented using luting glass ionomer cement (GIC). The crown will be held with firm, constant pressure until the cement sets initially.~ 6.The marginal fit will be evaluated, and necessary adjustments will be made. 7.The occlusion will be checked,"

OTHER

(Group B: Preformed Zirconia crown)

1\. Crown Selection: The mesiodistal dimension of the corresponding tooth will be measured . to select the appropriate size.2. Occlusal Reduction: The marginal ridge of adjacent teeth will be used as a reference point and a 1.5-2 mm of occlusal reduction will be performed to allow proper crown seating.3. Bucco-Lingual Reduction: The bucco-lingual wall will be reduced by approximately 1-1.5 mm using a flame-shaped diamond bur.4. Interproximal Reduction: 1 mm of interproximal reduction will be performed using a flame-shaped diamond bur such as a .368 or .330 tapered carbide bur.5. Feather Margin Preparation: Subgingival reduction of 1-2 mm will be done using a flame-shaped diamond bur, creating a feathered margin to achieve a passive fit.6. Trial Fitting of the Crown: The crown will be tried in to ensure proper adaptation. until the crown fits passively and extends sub gingivally by 1-2 mm wit.7. Glass ionomer cement will be used for cementation.

Trial Locations (2)

12613

Faculty of Dentistry, Cairo University., Cairo

Unknown

Faculty of Dentistry, Cairo University., Cairo

All Listed Sponsors
lead

Cairo University

OTHER

NCT06856070 - Retention of Bioflx Crowns Compared to Zirconia Crowns on Primary Molars | Biotech Hunter | Biotech Hunter