Virtual Reality and Laser Biostimulation on Pain Perception and Dental Anxiety

NACompletedINTERVENTIONAL
Enrollment

40

Participants

Timeline

Start Date

January 3, 2023

Primary Completion Date

April 25, 2023

Study Completion Date

May 15, 2023

Conditions
Dental AnxietyPain Intensity Assessment
Interventions
OTHER

Distraction with Virtual reality glassess

the injection site was dried with a cotton pellet and placebo topical anaesthesia was applied with a pre-sterilised wooden ear stick in a circular motion followed by laser biostimulation. The Wiser diode laser (Doctor Smile, Vicenza, Italy), a diode laser device with a wavelength of 980 nm and equipped with a 600 μm diameter fibre, was used to deliver low-level laser therapy to the area of interest. The tip of the laser carrier system was placed at a distance of 1 cm from the target tissue without contact and applied with continuous circular movements as recommended by the manufacturer. A silicone piece was placed on the end of the carrier system to ensure that the distance to the tissue remained constant in each application. The focal spot area was determined as 0.087 cm2. The power of the laser used in our study was determined as 0.3 W and the application time was selected as 60 seconds. The patient and the physician wore protective goggles during the whole procedure to prevent possi

OTHER

Distraction with Virtual reality glassess + LLLT

The injection area was dried with a cotton pellet before injection. A topical anaesthetic gel containing 20% benzocaine (Vision pat gel) was applied to the mucosal tissues to be injected using a pre-sterilised ear stick. After the application of the topical anaesthetic agent, the laser device was positioned in the same way, but without applying energy, and the sound of the laser device was pre-recorded and the study was blinded. In this way, a placebo effect was created and the patient was prevented from distinguishing between the laser and non-laser session. After this procedure, local anaesthesia was applied.

OTHER

Tell Show Do Group + LLLT

The injection site was dried with a cotton pellet and placebo topical anaesthesia was applied with a pre-sterilised wooden ear stick in a circular motion followed by laser biostimulation. The Wiser diode laser (Doctor Smile, Vicenza, Italy), a diode laser device with a wavelength of 980 nm and equipped with a 600 μm diameter fibre, was used to deliver low-level laser therapy to the area of interest. The tip of the laser carrier system was placed at a distance of 1 cm from the target tissue without contact and applied with continuous circular movements as recommended by the manufacturer. A silicone piece was placed on the end of the carrier system to ensure that the distance to the tissue remained constant in each application. The focal spot area was determined as 0.087 cm2. The power of the laser used in our study was determined as 0.3 W and the application time was selected as 60 seconds. During the whole procedure, the patient wore virtual glasses and the physician wore protective go

OTHER

Tell Show Do Group

In this session, the injection area was dried with a cotton pellet before injection. A topical anaesthetic gel containing 20% benzocaine (Vision pat gel) was applied to the mucosal tissues to be injected using a pre-sterilised ear stick. After the application of the topical anaesthetic agent, the laser device was positioned in the same way, but without applying energy, and the sound of the laser device was pre-recorded and the study was blinded. In this way, a placebo effect was created and the patient was prevented from distinguishing between the laser and non-laser session. After this procedure, local anaesthesia was applied.

Trial Locations (1)

34147

Altinbas University Faculty of Dentistry, Istanbul

All Listed Sponsors
lead

SIRIN GUNER ONUR

OTHER