The Effect of Vitamin D and Calcium Supplement on Overall Body Bone Density and Implant Stability in Posterior Maxilla

NACompletedINTERVENTIONAL
Enrollment

12

Participants

Timeline

Start Date

October 2, 2021

Primary Completion Date

March 1, 2023

Study Completion Date

March 1, 2023

Conditions
Dental Implant
Interventions
PROCEDURE

Patients received vitamin D and calcium supplementation during the healing period

"The proposed implant site and adjacent tissues were disinfected using betadine mouthwash, and standard infiltration anesthesia was administered both buccally and palatally. A paracrestal incision was then made over the intended implant location, and the mucoperiosteal flap was elevated to expose the underlying bone. Subsequently, an osteotomy was prepared using a 2.0 mm pilot drill, maintaining irrigation with sterile saline. The osseodensification protocol was employed with Densah burs in increasing diameters (2 mm, 3 mm, 4 mm) under copious irrigation. Throughout the osteotomy preparation, implant angulation was regularly checked using a paralling pin. Upon encountering haptic feedback, pressure was modulated to achieve the desired depth. The implant was then installed using a surgical handpiece, and the final insertion torque was recorded using a torque wrench, ensuring successful placement.~During the healing period, the patients recieved Vitamin D and Calcium Supplements."

PROCEDURE

Patients have not received any nutritional supplementation during the healing period.

The proposed implant site and adjacent tissues were disinfected using betadine mouthwash, and standard infiltration anesthesia was administered both buccally and palatally. A paracrestal incision was then made over the intended implant location, and the mucoperiosteal flap was elevated to expose the underlying bone. Subsequently, an osteotomy was prepared using a 2.0 mm pilot drill while maintaining irrigation with sterile saline. The osseodensification protocol was employed with Densah burs in increasing diameters (2 mm, 3 mm, 4 mm) under copious irrigation. Throughout the osteotomy preparation, implant angulation was regularly checked using a paraling pin. Upon encountering haptic feedback, pressure was modulated to achieve the desired depth. The implant was then installed using a surgical handpiece, and the final insertion torque was recorded using a torque wrench, ensuring successful placement. During the healing period, the patients did not receive vitamin or calcium supplements.

Trial Locations (1)

Unknown

Alazhar University, Asyut

All Listed Sponsors
lead

Al-Azhar University

OTHER

NCT06673485 - The Effect of Vitamin D and Calcium Supplement on Overall Body Bone Density and Implant Stability in Posterior Maxilla | Biotech Hunter | Biotech Hunter