18
Participants
Start Date
January 12, 2021
Primary Completion Date
September 28, 2021
Study Completion Date
September 28, 2021
Osseodesification densah burs
"Drill no. VT1525 (2mm) of densah burs will be used first in counter clockwise (in the osteotomy site).~Then drill no. VT2535 (3mm) of densah burs will be used in counter clockwise to put 3.5mm implant diameter."
Microdent
"No. 1 Microdent expander will be placed and screwed slowely (to avoid heat generation) into the osteotomy site till reaching the full desired length.~N0. 2 microdent expander will be placed and screwed into the osteotomy site as the same step.~Then no. 3 Microdent expander will be inserted for placing 3.5mm implant diameter"
Outpatient Clinic of Periodontology and Oral medicine Department, Faculty of Dentistry, Alexandria University, Egypt, Alexandria
Hams Hamed Abdelrahman
OTHER