64
Participants
Start Date
December 2, 2020
Primary Completion Date
November 21, 2023
Study Completion Date
January 24, 2024
VFQ- 25 (Visual Function Questionnaire)
VFQ-25 questionnaire was used to evaluate patient satisfaction at the M3 and M12 visits.
Optical Biometry
Axial length, anterior chamber depth and corneal keratometric values K1-K2. All these parameters were measured at the screening visit and at the month 3 follow-up visit, using the ARGOS® Biometer or the ANTERION® Cataract App
Slit lamps / Fundoscopy / Biomicroscopy
The fundus and other ocular structures, such as the cornea, anterior chamber, iris, pupil, crystalline lens / IOL alignment, corpus ciliare and choroid were examined at screening visit, on the day of the surgery, and at the follow up visits D1, M1, M3, M6, and M12, using the slit lamp binocular indirect ophthalmoscopy.
UDVA
Monocular and binocular Uncorrected Distance Visual Acuity (UDVA) was evaluated at all visits (preoperative, D1, M1, M3, M6 and M12), using the ETDRS chart.
CDVA
Monocular and binocular Corrected Distance Visual Acuity (UDVA) was evaluated at all visits (preoperative, D1, M1, M3, M6 and M12), using the ETDRS chart.
UIVA / DCIVA
Uncorrected and Distance Corrected Intermediate Visual acuity (UIVA / DCIVA) was evaluated postoperatively at M1, M3, M6 and M12, using an intermediate chart from 67 cm.
UNVA / DCNVA
Uncorrected and Distance Corrected Near Visual acuity (UNVA / DCNVA) was evaluated postoperatively at M1, M3, M6 and M12, using a near chart from 40 cm.
Manifest Refraction
Manifest refraction was the monocular subjective refraction (Sph, Cyl, Axis) giving the best distance corrected visual acuity. It was measured at the screening visit and the follow-up visits Day 1, Month 1, Month 3, Month 6 and Month 12.
IOP
Intraocular pressure (IOP) was measured at all visits (preoperative, D1, M1, M3, M6 and M12), using a non-contact tonometer.
VADC
Visual Acuity Defocus Curve (VADC) was taken monocularly at M3, monocularly and binocularly at M6 and binocularly at M12, using the Multifocal Lens analyzer - MLA application.
CSDC
Contrast Sinsitivity Defocus Curve (CSDC) was taken under photopic conditions at M6 and M12, using the Multifocal Lens Analyzer - MLA application
CSV-1000
"Contrast Sensitivity was measured using the CSV-1000 with distance correction in place at spatial frequencies of 3, 6, 12, and 18 cycles per degree (cpd). Measurements were taken under four different light conditions:~* Photopic (M3 monocular and binocular, M6 binocular and M12 monocular)~* Mesopic (M6 binocular)~* Photopic with backlight (M6 binocular)~* Mesopic with backlight (M6 binocular)"
Tear film stability
Tear film stability was assessed at screening visit and at follow-up visits M1, M3, M6, and M12 using the non-invasive Tear break Up Time (TBUT) with fluorescein dye.
IOL implantation
The investigational device (877PEY) and the comparator (877PAY) intraocular lens models were implanted, using sutureless, small-incision phacoemulsification surgery.
Borsod-Abaúj-Zemplén Vármegyei Központi Kórház és Egyetemi Oktatókórház, Miskolc
Retinaszerviz Kft., Veszprém
Győr-Moson-Sopron Vármegyei Petz Aladár Egyetemi Oktató Kórház, Győr
Medicontur Medical Engineering Ltd
INDUSTRY