270
Participants
Start Date
August 1, 2024
Primary Completion Date
August 1, 2026
Study Completion Date
September 30, 2026
PRF+PRP, PRF
Under CT guidance, the trocar then was inserted through the ipsilateral foramen ovale to the Gasserian ganglion of the patient. After puncturing the foramen ovalis, remove the cannula needle core and connected with RF electrode (PMK-21-100, Baylis, Canada) and the RF generator. Electrical stimulation was carried out at 50 Hz to determine the sensory threshold and at 2 Hz to determine the motor threshold. The RF generator was set to the manual PRF mode with a standard setting of 42°C, the UP knob was turned to increase the output voltage until the maximum voltage (bearable without causing pain in conscious patients)was reached; 120 s, 2 times. After removing the RF electrode in the combined treatment group, 2ml of LP-PRP mixture was injected slowly into the Gasserian ganglion and mandibular nerve and PRF group only receive PRF treatment.
RECRUITING
Beijing Tiantan Hospital, Capital Medical University in Beijing, Beijing
Beijing Tiantan Hospital
OTHER