Evaluating Fluid Responsiveness in ICU Patients Using VTI and Trendelenburg Positioning

NARecruitingINTERVENTIONAL
Enrollment

400

Participants

Timeline

Start Date

April 1, 2024

Primary Completion Date

April 1, 2025

Study Completion Date

August 1, 2025

Conditions
ShockFluid OverloadCardiac Output, Low
Interventions
DEVICE

Trendelenburg positioning VTI

"There are essentially two arms, whereby the patients is being compared to themselves. The intervention arm is the same patient undergoing TP from the baseline supine position to determine the change in VTI after subjecting to TP.~We will be using a Sonosite PX ultrasound system, which is intended for diagnostic ultrasound imaging or fluid flow analysis of the human body and, more specifically, for our echocardiographic measurements of velocity time integral (VTI; surrogate for stroke volume and cardiac output). The Sonosite PX is a general-purpose ultrasound system intended for use by qualified physicians and healthcare professionals, for evaluation by ultrasound imaging or fluid flow analysis of the human body. This is an FDA-cleared (510K# K200964) commercial device legally marketed in the United States that is being used in accordance with labeling."

Trial Locations (1)

10075

RECRUITING

Lenox Hill Hospital- Northwell Health, New York

All Listed Sponsors
lead

Lenox Hill Hospital

OTHER