88
Participants
Start Date
May 13, 2024
Primary Completion Date
September 23, 2024
Study Completion Date
September 30, 2024
Ultrasound-guided median nerve hydrodissection
Injected wrist will be supinated and slightly dorsiflexed. The transducer of the ultrasound will be placed transversely at the proximal carpal inlet. After sterile preparation, a 22 gauge needle will be inserted using the short-axis technique, in-plane ulnar approach. During hydrodissection, separation of either between the median nerve and flexor retinaculum or between the median nerve and the underlying flexor tendons will be visually confirmed.
Istanbul University - Cerrahpasa (IUC), Istanbul
Istanbul University - Cerrahpasa
OTHER