DEEP mapping
"The Substrate-based DEEP Mapping aims to identify the arrhythmogenic substrate of VT in sinus rhythm (SR). A standardized VT mapping and ablation procedure in SR has been proven effective in reducing VT recurrences in a multicenter setting by targeting late potential (LP) abolition. Regions with LPs and LAVAs that displayed decremental behavior evoked during right ventricular (RV) pacing with extra stimuli (decrement-evoked potential; DEEP), colocalized with the regions of the initiation and diastolic pathway of the VT more accurately than those areas displaying non decremental LPs.~Device use for mapping and ablation procedure:~FlexAbility/Tactiflex/TactiCath Ablation Catheter Sensor Enabled (Abbott, MN), high-density grid mapping catheter (GMC; Advisor HD Grid Mapping Catheter Sensor Enabled, Abbott, MN)"
Activation Mapping
"VT Activation Mapping can localize reentry circuits, and the diastolic pathway isthmus is the desirable target for ablation when possible because it can eliminate the elements required for reentry. In fact, activation mapping of the entire diastolic pathway is associated with higher freedom from VT recurrences compared to substrate modification~Device use for mapping and ablation procedure:~FlexAbility/Tactiflex/TactiCath Ablation Catheter Sensor Enabled (Abbott, MN), high-density grid mapping catheter (GMC; Advisor HD Grid Mapping Catheter Sensor Enabled, Abbott, MN)"
RECRUITING
San Raffaele Hospital, Milan
IRCCS Ospedale San Raffaele
OTHER