Digital Confocal Microscopy for Real-time Diagnosis of Pancreatic Solid Lesion

CompletedOBSERVATIONAL
Enrollment

78

Participants

Timeline

Start Date

January 1, 2023

Primary Completion Date

November 30, 2023

Study Completion Date

November 30, 2023

Conditions
Pancreas AdenocarcinomaEndoscopic UltrasoundDigital Pathology
Interventions
PROCEDURE

Endoscopic ultrasound fine needle biopsy

"EUS FNA/B for solid pancreatic lesions. After the FNA/FNB, the needle was removed from the EUS endoscope and the specimen obtained after the first needle pass was expelled and placed directly in a dedicated scaffold (Cytomatrix, UCS Diagnostics).~a drop of ethanol was put on it and the liquid was drained away thanks to the porous structure of the matrix. This step was followed by the deposition of a drop of acridine-orange for 20 and a rapid washing with buffered saline. After that, the Cytomatrix was put on a dedicated microscopic slide and covered with a second slide before the introduction in the slot of the machine.~The FCM VivaScope® 2500 (2500M-G4; VivaScope, Munich, Germany) was used for immediate imaging."

Trial Locations (1)

00191

Fondazione Policlinico Campus Bio Medico, Rome

All Listed Sponsors
lead

Campus Bio-Medico University

OTHER