Comparison of Two Different Lightwand Intubation Techniques in Cervical Immobilized Patients

NACompletedINTERVENTIONAL
Enrollment

176

Participants

Timeline

Start Date

December 12, 2018

Primary Completion Date

February 13, 2019

Study Completion Date

August 31, 2019

Conditions
Intubation; Difficult or Failed
Interventions
PROCEDURE

Face-to-face approach

A front-facing approach and insert the lightwand following the patient's tongue base curvature without scooping movement

PROCEDURE

Conventional approach

Patients were positioned supine and the intubator stood above the patient's head. Opening the mouth and slightly pulling the mandible with one hand, the intubator inserted the lightwand-tracheal tube assembly at midline into the patient's mouth under the ambient light being turned off. To identify the location of the lighted tip, the intubator could move the lightwand back and forth gently, Once the red light of the tip was located at the midline of the patient's neck, the pre-launched tube was inserted smoothly into the patient's airway unless there was no resistance

Trial Locations (1)

05278

Kyung Hee University Gangdong Hospital, Seoul