Impact Evaluation of Incisional Hernia on Muscular and Postural Function

NACompletedINTERVENTIONAL
Enrollment

95

Participants

Timeline

Start Date

January 2, 2018

Primary Completion Date

December 31, 2022

Study Completion Date

May 15, 2023

Conditions
Incisional Hernia
Interventions
DIAGNOSTIC_TEST

Dynamometric tension assessment

"Tension dynamometry was carried out using the Back-Check 600 diagnostic complex by Dr.WOLFF® (GmbH, Germany). The dynamometric stress assessment included tasks for flexion and extension of the body. The functional assessment of the abdominal wall muscles was assessed when preparing the patient for surgery (1-10 days before AWR-abdominal wall reconstruction) and 6 months after AWR."

DIAGNOSTIC_TEST

Postural balance

"Postural balance was assessed using raster photostereography and baropodometry on the DIERS diagnostic complex by Formetric-4D (GmbH, Germany). When analyzing the topography of the optical field, muscle imbalance is revealed in the form of lateral deviation and inclination of the trunk and pelvis, as well as the values of the angle of kyphosis and lordosis. When conducting baropodometry, the level of displacement of the pressure area on the feet of patients in a static and dynamic position was assessed. Diagnosis of postural balance in patients with incisional ventral hernia was performed a few days before surgical treatment and 6 months after AWR."

DIAGNOSTIC_TEST

Assessment of the hernia defect size

"Parameters of the hernial defect, including the volume of the hernial sac, the diameter of the hernial orifice, the ratio of hernia volume to the abdominal cavity volume, were performed using preoperative (1-10 days before AWR) multispiral computed tomography on a GE BrightSpeed 16 tomograph (General Electric©, USA)"

DIAGNOSTIC_TEST

Physical activity of patients

"To analyze the physical activity of patients, the measurement of the number of steps was used. The measurements of steps and the amount of distance traveled were carried out using a physical activity monitor - a fitness bracelet MiBAND (China). Measurements were taken 10 days before AWR and within 6 months after AWR."

Trial Locations (1)

100100

Republican specialized scientific practical medical center of surgery named after V.V. Vakhidov, Tashkent

All Listed Sponsors
collaborator

Tashkent state dental institute

UNKNOWN

collaborator

I.M. Sechenov First Moscow State Medical University

OTHER

collaborator

Pirogov Russian National Research Medical University

OTHER

lead

Republican Specialized Scientific and Practical Medical Center of Surgery Named After V. Vakhidov

OTHER

NCT05990647 - Impact Evaluation of Incisional Hernia on Muscular and Postural Function | Biotech Hunter | Biotech Hunter