Cardiac Resynchronization Therapy Devices with Defibrillator Function (CRT-D) or CRT-D Leads Replacement
The local anesthesia will be performed on the left/right subclavian area after prepping the skin. The device pocket will be opened, the old CRT-D will be removed and disconnected from the leads. The pacing threshold, intracardiac signal amplitude and impedance (pacing and shock) on the atrial, defibrillation and left ventricular leads will be performed. If there is a lead dysfunction, the new lead will be implanted. The new CRT-D will be connected with leads and placed back into the pocket. The pocket will be closed by separate stitches (2-4 suffice) using the resorbable braided suture.
CRT-D or CRT-D Leads Replacement with New Lead Implantation to Left Bundle Branch and Inactivation of Conventional Right and Left Ventricular Pacing
The local anesthesia will be performed on the left/right subclavian area after prepping the skin. The device pocket will be opened, the old CRT-D will be removed and disconnected from the leads. The pacing threshold, intracardiac signal amplitude and impedance (pacing and shock) on the atrial, defibrillation and left ventricular leads will be performed. If there is a lead dysfunction, the new lead will be implanted. The lead implantation to the left bundle branch (LBB) will be performed by transvenous approach and special delivery system. The new CRT-D will be connected with the leads (LBB pacing lead will be connected to defibrillation lead (DL) IS-1 connector of CRT-D and IS-1 tip of DL will be capped) and placed back into pocket. The pocket will be closed by separate stitches (2-4 suffice) using the resorbable braided suture. RV and LV pacing will be inactivated and only LBB pacing will be switched on.
CRT-D or CRT-D Leads Replacement with New Lead Implantation to Left Bundle Branch and Inactivation of Conventional Right Ventricular Pacing
The local anesthesia will be performed on the left/right subclavian area after prepping the skin. The device pocket will be opened, the old CRT-D will be removed and disconnected from the leads. The pacing threshold, intracardiac signal amplitude and impedance (pacing and shock) on the atrial, defibrillation and left ventricular leads will be performed. If there is a lead dysfunction, the new lead will be implanted. The lead implantation to the left bundle branch (LBB) will be performed by transvenous approach and special delivery system. The new CRT-D will be connected with the leads (LBB pacing lead will be connected to defibrillation lead (DL) IS-1 connector of CRT-D and IS-1 tip of DL will be capped) and placed back into pocket. The pocket will be closed by separate stitches (2-4 suffice) using the resorbable braided suture. LBB and LV pacing will be switched on.