42
Participants
Start Date
November 28, 2023
Primary Completion Date
February 27, 2026
Study Completion Date
November 28, 2026
simultaneous integrated boost of carbon ions radiation therapy
"CIRT Treatment will be delivered in 16 fractions, 4 fractions per week. Treatment plans will be calculated with a Simultaneous Integrated Boost Approach (SIB).~The HR-CTV will receive a total dose of 65.6 GyRBE (4.1 GyRBE/fraction). The LR-CTV will simultaneously receive a total dose of 54.4 GyRBE (3.4 GyRBE/fraction) or 48 GyRBE (3 GyRBE/fraction) at discretion of Radiation Oncologist depending on the prognostic factors (54.4 GyRBE in case of macroscopical perineural invasion or positive margin along the nerve, 48.0 Gy(RBE) in case of elective perineural irradiation or microscopic focal intratumor perineural invasion)."
RECRUITING
CNAO, Pavia
CNAO National Center of Oncological Hadrontherapy
OTHER