Efficacy of Electric Fans for Mitigating Thermal Strain in Older Adults During Heat Waves

NACompletedINTERVENTIONAL
Enrollment

19

Participants

Timeline

Start Date

December 1, 2022

Primary Completion Date

April 10, 2023

Study Completion Date

April 10, 2023

Conditions
HyperthermiaWeather; HeatHeat StressAging
Interventions
OTHER

No cooling (control)

Participants are exposed to 36°C, 45% relative humidity for 8 hours without cooling intervention (control condition). Drinking water is available ad libitum. Participants are seated throughout exposure, except for during 10 min periods of simulated activities of daily living (light stepping at 2-2.5 METS) performed at hours 1, 3, 5, and 7.

OTHER

Electric fan (low airflow)

Participants are exposed to 36°C, 45% relative humidity for 8 hours without cooling interventions (control condition). Drinking water is available ad libitum. Participants are seated throughout exposure, except for during 10 min periods of simulated activities of daily living (light stepping at 2-2.5 METS) performed at hours 1, 3, 5, and 7. While participants are seated, an electric pedestal fan positioned 1 m away will deliver a continuous airflow of 2 m/s to the front of the body.

OTHER

Electric fan (high airflow)

Participants are exposed to 36°C, 45% relative humidity for 8 hours without cooling interventions (control condition). Drinking water is available ad libitum. Participants are seated throughout exposure, except for during 10 min periods of simulated activities of daily living (light stepping at 2-2.5 METS) performed at hours 1, 3, 5, and 7. While participants are seated, an electric pedestal fan positioned 1 m away will deliver a continuous airflow of 4 m/s to the front of the body.

Trial Locations (1)

K1N6N5

University of Ottawa, Ottawa

All Listed Sponsors
lead

University of Ottawa

OTHER