60
Participants
Start Date
December 13, 2021
Primary Completion Date
July 9, 2022
Study Completion Date
July 31, 2022
Automatic Mechanical Ventilation
"Ventilation settings:~Mode: (S)Continuous Mandatory Ventilation Rate: 10 b/min. Tidal Volume: 500 ml (male), 450 ml (female) I:E=1:1 Positive end expiratory pressure (PEEP): 5 cmH2O Flow trigger: off Oxygen: 100% Alarms: Pressure 70 cmH20, Tidal volume 100 \~ 1,000 ml"
Manual Ventilation
Ambu-bagging (It is recommended in the guidelines as a ventilation method.) Methods: 10 times per minutes by medical personnel
Seoul Metropolitan Goverment-Seoul National University Boramae Medical Center, Seoul
Seoul National University Hospital
OTHER