233
Participants
Start Date
August 1, 2015
Primary Completion Date
October 31, 2018
Study Completion Date
December 31, 2021
PETMRI
PET/MRI data will be acquired on the integrated PET/MRI scanner. After fast-view T1-weighted MR localizer sequence for scout imaging and Dixon VIBE sequence for attenuation correction, a whole-body PET scan will be performed to cover from the head to the proximal thigh, with an acquisition time of 4 min per bed position. Simultaneously, whole body MR image acquisition will be performed with the axial HASTE sequence and coronal STIR sequence as well as the sagittal T1-weighted Turbo spine echo and STIR sequence. Afterwards, regional PET and MRI images will be simultaneously performed. DWI will be performed using a single shot spin-echo echo-planar technique. A total of 10 b values will be used for the reconstruction of IVIM and kurtosis imaging. DCE-PWI will be acquired by using a 3D T1-weighted spoiled gradient-echo sequence. Thereafter, dedicated regional MRI will be obtained. Finally, whole body axial VIBE with fat saturation will be performed.
Department of Medical Imaging and Intervention, Chang Gung Memorial Hospital, Guishan
Chang Gung Memorial Hospital
OTHER