Comparison of Robotic Arm-assisted PET/CT-guided Lung Biopsy With PET Fused CT- Fluoroscopy-guided Lung Biopsy

CompletedOBSERVATIONAL
Enrollment

59

Participants

Timeline

Start Date

July 1, 2020

Primary Completion Date

December 31, 2021

Study Completion Date

January 31, 2022

Conditions
Lung CancerLung DiseasesAdenocarcinoma of Lung
Interventions
PROCEDURE

Robotic arm assisted PET/CT guided biopsy

"After preparing the participant for the procedure, the participant was positioned on the PET/CT table with the immobilizer.~An automated robotic arm (MAXIO-EX, Perfint healthcare Pvt Ltd, Chennai, India) was used to guide the needle for biopsy.~Co-axial 18 G biopsy needle (BARD Biopsy disposable coaxial biopsy needle pack, Bard Peripheral Vascular, Inc., Arizona, USA) was inserted according to the orientation planned by the robotic biopsy device.~After the location is ensured, the trocar stylet is removed from the coaxial cannula and specimens were retrieved using a semiautomated biopsy gun.~A repeat CT chest was acquired two hours after the procedure to rule out post-procedural complications.~Complications during the procedure were noted, and immediate management was done."

PROCEDURE

PET fused CT-Fluoroscopy guided biopsy

CT fluoroscopy was used to place the biopsy needle to the FDG avid lung lesion

Trial Locations (1)

160012

Department of Nuclear Medicine, PGIMER, Chandigarh