Is Carotid-Vertebral Doppler Ultrasonography Necessary for Patients With Vertigo?

CompletedOBSERVATIONAL
Enrollment

195

Participants

Timeline

Start Date

February 1, 2021

Primary Completion Date

August 1, 2022

Study Completion Date

August 31, 2022

Conditions
VertigoCarotid Artery Diseases
Interventions
DIAGNOSTIC_TEST

Carotid Doppler USG

All Doppler ultrasonography measurements will be made in a dimly lit room at room temperature, with the patient in the supine position, the head slightly hyperextended, the patient looking to the left when measuring the right side, and the patient looking to the right when measuring the left side. In all patients, common carotid artery (CCA), internal carotid artery (ICA) and vertebral artery (VA) gray scale and color Doppler ultrasonography wşll be performed using the GE 9L Linear Probe. Color Doppler examination will be performed with a frequency of 4.0/8.0 MHz.

Trial Locations (1)

20070

Pamukkale University, Denizli

All Listed Sponsors
lead

Pamukkale University

OTHER

NCT05196685 - Is Carotid-Vertebral Doppler Ultrasonography Necessary for Patients With Vertigo? | Biotech Hunter | Biotech Hunter