TACE
Through a 7 French sheath placed through a single femoral arterial puncture, a guide catheter (Cobra 1 Guide Catheter, Mach 1, Boston Scientific Corporation, Marlborough, USA) is placed at the coeliac axis. From the digital subtraction angiography (DSA), the number of arterial tumor feeders to the HCC is identified. One or more feeder(s) is to be catheterized for delivery of therapeutic agent using a 2.4 French microcatheter (Merit Maestro, Merit Medical Systems, Utah, USA), and the other feeder(s) is occluded with a balloon catheter using 0.1 to 0.2mL diluted contrast for inflation (4mm x 10mm Temporary Occlusion Balloon Catheter, Occlusafe, Terumo Clinial Supply, Gifu, Japan). The occlusion target could be a feeder or a common trunk leading to a number of feeders. The therapeutic agent was delivered under fluoroscopic control until the vasculature of the whole tumors is entirely filled, which was assessed with DSA and non-contrast CT performed at the completion of the procedure.