Risk of Asymptomatic Cerebral Embolism During AF Ablation With AI-HPSD Strategy Versus Standard Settings

NACompletedINTERVENTIONAL
Enrollment

100

Participants

Timeline

Start Date

June 17, 2020

Primary Completion Date

September 13, 2021

Study Completion Date

December 31, 2021

Conditions
Atrial Fibrillation
Interventions
PROCEDURE

Ablation Index Guided High-Power Short-Duration Strategy

Point-by-point circumferential pulmonary vein ablation will be performed using the advanced STSF catheter under ablation index guided high power short duration strategy (Radiofrequency energy is set up at a power of 50 W, temperature of 43 °C, contact force of 5-20 gram, and flow rate of 20 mL/min; Target ablation index is set to 500 at the anterior wall and 350 at the posterior wall of left atrium).

PROCEDURE

Standard Radiofrequency Ablation Technique

Point-by-point circumferential pulmonary vein ablation will be performed using the ST catheter under standard radiofrequency ablation settings (Radiofrequency energy is set up at a power of 30 to 35 W, temperature of 43 °C, contact force of 5-20 gram, and flow rate of 17 to 30 mL/min. Target ablation index is set to 500 at the anterior wall and 350 at the posterior wall of left atrium).