Management of Cystoid Macular Edema Secondary to Retinitis Pigmentosa Via Subliminal Micropulse Yellow Laser

NACompletedINTERVENTIONAL
Enrollment

32

Participants

Timeline

Start Date

January 1, 2018

Primary Completion Date

October 30, 2019

Study Completion Date

December 30, 2019

Conditions
Retinitis PigmentosaCystoid Macular Edema
Interventions
DEVICE

SL-MPL treatment protocol was performed with a 577 nm yellow laser (EasyRet, Quantel Medical, Cedex, France)

Macular laser treatment was applied after pupil dilation and topical anesthesia. Laser application was performed with a Mainster Standard contact laser lens (Volk Optical, Mentor, OH, USA). To determine the appropriate personalized calibration value, single-spot test shot was applied under the green filter to a non-edematous area of the macula outside the temporal vascular arcade. The laser power was gradually increased until it formed a barely visible laser spot. The power of the micropulse pattern laser was set at 50% of the power needed to form a barely visible laser spot. Laser parameters used were 200 ms duration, 160 µm spot diameter, low operating cycle (5%), and zero spacing with 5x5 pattern shape. SL-MPL was applied to the areas where edema was detected in OCT and examination.

Trial Locations (2)

06312

Ankara University Biotechnology Institute, Ankara

Umut Arslan, Ankara