45
Participants
Start Date
November 28, 2019
Primary Completion Date
May 28, 2021
Study Completion Date
May 28, 2021
Low CT scanner without injection dose
CT scan acquisition will be performed at 140 kVp (kilovolt peak), 10 mAs(milliampere), CTDI 1.3 mGy with an irradiation dose 0.51 mSv (milliSievert). The CT image will be reconstructed and analyzed in parenchyma window. The CT images will be blinded and re-read by two independent senior radiologists 3 to 6 weeks apart between each re-reading.
Ultra-low dose CT scanner without injection
CT acquisition will be performed at 80 kVp for patient with a body mass index\<30, and 100 kVp with a body mass index\>30, 10 mAs, CTDI 0.3 and 0.6 mGy with an irradiation dose 0.15-0.30 mSv. The CT images will be reconstructed and analyzed in mediastinal window. The CT images will be blinded and re-read by two independent senior radiologists 3 to 6 weeks apart between each re-reading.
Hospices Civils de Lyon - Hopital Louis Pradel, Bron
Hospices Civils de Lyon
OTHER