Implants Immediately Installed in Esthetic Area With Computer-guided Surgery

NACompletedINTERVENTIONAL
Enrollment

40

Participants

Timeline

Start Date

April 10, 2019

Primary Completion Date

February 28, 2025

Study Completion Date

February 28, 2025

Conditions
Dental Implants
Interventions
DEVICE

Guided surgery with bovine spongious bone substitute

"A minimally traumatic extraction will be performed aiming at the preservation of tissue integrity. After this step, milling will be performed using a sequence of guides and cutters recommended by the Raptor Implacil / Bioparts (Implacil De Bortoli) system manufacturer for implant installation (Cone Morse 3.5mm from 11-13mm Implacil De Bortoli) in computer-guided surgeries.~In the spaces between the implant and the buccal bone plate will be filled with xenogene biomaterial (Geistlich Bio-Oss 0.25-1mm). Immediately after implant installation, the prosthetic component (Smart Line, Trunnion CM 3.5mm - T 1.5-3.5mm, height 4mm - Implacil De Bortoli) will be placed.~If necessary, the sutures of the surgical procedures will be performed with polygalactin 5.0 (Vycril Rapid®, Jonhson's Jonhson, São José dos Campos) and will be removed after 7 days."

DEVICE

Conventional surgery with bovine spongious bone substitute

The sequence of cutters recommended by the manufacturer for this type of surgery and installation of the same type of implant (Cone Morse due cone 3.5mm) will be adopted. The perforations of the collar for future insertion of the implants will be performed aiming the installation of the implants with its platform installed with sub-crestal position. The implant should be installed along the palatine wall to obtain primary stability, at the center of the mesio-distal width predetermined by the final restoration, with a minimum distance of 2 mm from the adjacent tooth, and 3 mm from the free gingival margin, becoming slightly palatinate (Kan et al, 2018). Immediately after installation, the prosthetic component (Smart Line, Trunnion CM 3.5mm - T 1.5-3.5mm, height 4mm) will be placed. If necessary, the sutures of the surgical procedures will be performed with polygalactin 5.0 (Vycril Rapid®, Jonhson's Jonhson, São José dos Campos) and will be removed after 7 days.

Trial Locations (1)

13414-903

Piracicaba Dental School, State University of Campinas, Piracicaba

All Listed Sponsors
lead

University of Campinas, Brazil

OTHER

NCT03986164 - Implants Immediately Installed in Esthetic Area With Computer-guided Surgery | Biotech Hunter | Biotech Hunter