Different Suction Techniques For Endoscopic Ultrasound-Guided Fine-Needle Biopsy In Pancreatic Solid Lesions

NACompletedINTERVENTIONAL
Enrollment

110

Participants

Timeline

Start Date

May 1, 2017

Primary Completion Date

May 31, 2018

Study Completion Date

May 31, 2018

Conditions
Pancreatic Solid Lesions
Interventions
DEVICE

Stylet slow-pull technique

During endosonographic examination, the pancreatic mass was evaluated with color Doppler to avoid the involvement of vessels. The needle (20 Gauge, EchoTip ProCore 20G with ReCoil Stylet™, Cook Medical, Bloomington, IN, USA) was sharpened by withdrawing the stylet approximately 2 mm, and then was advanced into the lesion: 15 to-and-fro movements within the lesion were performed, with simultaneous minimal negative pressure provided by pulling the needle stylet slowly and continuously.

DEVICE

Standard suction technique

During endosonographic examination, the pancreatic mass was evaluated with color Doppler to avoid the involvement of vessels. The needle (20 Gauge, EchoTip ProCore 20G with ReCoil Stylet™, Cook Medical, Bloomington, IN, USA) was sharpened by withdrawing the stylet approximately 2 mm, and then was advanced into the lesion: 15 to-and-fro movements within the lesion were performed using a 10-mL suction syringe.

Trial Locations (1)

90127

ARNAS Civico - Di Cristina - Benfratelli Hospital, Palermo

All Listed Sponsors
lead

ARNAS Civico Di Cristina Benfratelli Hospital

OTHER

NCT03849209 - Different Suction Techniques For Endoscopic Ultrasound-Guided Fine-Needle Biopsy In Pancreatic Solid Lesions | Biotech Hunter | Biotech Hunter