120
Participants
Start Date
September 4, 2018
Primary Completion Date
November 8, 2018
Study Completion Date
February 20, 2019
ECG-EM Guidance
"ECG-EM method consists on a puncture of an arm vein, under the ultrasound control and local anesthesia. The length of the PICC is estimated prior to its insertion using morphological landmarks. The placement of the PICC is done using SHERLOCK 3CG™ Diamond Tip Confirmation System (TCS) \[CE marked device, C. R. Bard, Inc.\].~At the end of procedure, a chest x-ray is performed to assess the PICC position"
FX Guidance
"FX method consists on a puncture of an arm vein, under the ultrasound control and local anesthesia. Through the point of puncture, a long wire is then introduced and directed to the level of the target zone located in the superior vena cava under fluoroscopy control. The length of the guide inside the vessel is then measured to adjust the length of the PICC necessary for its optimal positioning.~At the end of procedure, a chest x-ray is performed to assess the PICC position"
CHUV, Lausanne
Centre Hospitalier Universitaire Vaudois
OTHER
Salah D. Qanadli
OTHER