54
Participants
Start Date
October 8, 2018
Primary Completion Date
December 30, 2019
Study Completion Date
May 31, 2020
Hybrid Dyna-CT guided localization
We will perform intraoperative lung tumor localization in CGMH hybrid operation room(Room 51) equipped with the Siemens Artis Zeego system with DynaCT imaging capabilities. The system provides images equivalent to a 16-slice spiral CT scanner in a single 6-s sweep.
Preoperative CT scan-guided localization
Preoperative localization of the lung nodule will be carried out in the radiology department on the day of surgery using local anesthesia. CT-guided hook-wire or methyl blue dye will be placed percutaneously through a 22-gauge needle with the distal end deep to the nodule. The patient will then be taken to the operating room, where under general anesthesia with lung isolation, the nodule will be removed by wedge excision with endostaplers (Endo-GIA-II, United States Surgical,Norwalk, Conn; Echelon Endostapler, Ethicon Endo-Surgery, Cincinnati,Ohio) under the guidance of preoperative lung marking. If the lesion could not be excised using the VATS technique, the patient underwent an open thoracotomy.
Chang Gung Memorial Hospital, Taoyuan District
Chang Gung Memorial Hospital
OTHER