Clinical Evaluation of Bulk Fill Composite Restorations Associated to Universal Adhesive System

NAActive, not recruitingINTERVENTIONAL
Enrollment

50

Participants

Timeline

Start Date

June 1, 2017

Primary Completion Date

September 1, 2019

Study Completion Date

September 30, 2026

Conditions
Dental Restoration Failure of Marginal Integrity
Interventions
PROCEDURE

SEE Strategy and Incremental Restoration

37% phosphoric acid will be applied during 30 seconds, only in enamel in 50 teeth. This acid will be removed using water, the cavity will be air-dried, and then, the adhesive will be brushed during 20 seconds in the cavity, will be air-dried during 5 seconds, and photoactivated during 10 seconds with Light Emission Diode (LED) light. Then, the Filtek Z350XT composite will be used in increments of no more than 2 mm, using the incremental restoration technique, and each increment will be photoactivated for 40 seconds.

PROCEDURE

SEE Strategy and Bulk Fill Restoration

37% phosphoric acid will be applied during 30 seconds, only in enamel in 50 teeth. This acid will be removed using water, the cavity will be air-dried, and then, the adhesive will be brushed during 20 seconds in the cavity, will be air-dried during 5 seconds, and photoactivated during 10 seconds with Light Emission Diode (LED) light. Then, the Filtek Bulk Fill composite will be used in increments of 4 mm, using the bulk restoration technique, and photoactivated for 40 seconds.

PROCEDURE

SET Strategy and Incremental Restoration

no conditioning, the adhesive system will be used in 50 teeth, according to the manufacturer's instructions, in the self-etching mode. The adhesive system will be brushed during 20 seconds in the cavity, will be air-dried during 5 seconds, and photoactivated during 10 seconds with Light Emission Diode (LED) light. Then, the Filtek Z350XT composite will be used in increments of no more than 2 mm, using the incremental restoration technique, and each increment will be photoactivated for 40 seconds.

PROCEDURE

SET Strategy and Bulk Fill Restoration

no conditioning, the adhesive system will be used in 50 teeth, according to the manufacturer's instructions, in the self-etching mode. The adhesive system will be brushed during 20 seconds in the cavity, will be air-dried during 5 seconds, and photoactivated during 10 seconds with Light Emission Diode (LED) light. Then, the Filtek Bulk Fill composite will be used in increments of 4 mm, using the bulk restoration technique, and photoactivated for 40 seconds.

Trial Locations (1)

28625-650

Universidade Federal Fluminense - School of Dentistry, Nova Friburgo

All Listed Sponsors
lead

Universidade Federal Fluminense

OTHER