Selecting the Best Ventilator Hyperinflation Settings

NACompletedINTERVENTIONAL
Enrollment

30

Participants

Timeline

Start Date

July 31, 2016

Primary Completion Date

August 31, 2017

Study Completion Date

August 31, 2017

Conditions
Respiratory FailureRespiration Disorders
Interventions
OTHER

VC-CMV20

Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV). The inspiratory flow was set at 20Lpm and the tidal volume was increased in steps of 200mL until the peak airway pressure of 40cmH2O was achieved. After achieving the target pressure, this ventilatory regimen lasted 15 minutes. Positive end expiratory pressure and the inspired oxygen fraction were not modified.

OTHER

VC-CMV50

Application of a ventilator hyperinflation intervention with Volume Control Continuous Mandatory Ventilation (VC-CMV). The inspiratory flow was set at 50Lpm and the tidal volume was increased in steps of 200mL until the peak airway pressure of 40cmH2O was achieved. After achieving the target pressure, this ventilatory regimen lasted 15 minutes. Positive end expiratory pressure and the inspired oxygen fraction were not modified.

OTHER

PC-CMV1

Application of a ventilator hyperinflation intervention with Pressure Control Continuous Mandatory Ventilation (PC-CMV1). The inspiratory time was set at 1 second and the pressure control was increased until a peak pressure of 40cmH2O was achieved. After achieving the target pressure, this ventilatory regimen lasted 15 minutes. Positive end expiratory pressure and the inspired oxygen fraction were not modified.

OTHER

PC-CMV3

Application of a ventilator hyperinflation intervention with Pressure Control Continuous Mandatory Ventilation (PC-CMV1). The inspiratory time was set at 3 seconds and the pressure control was increased until a peak pressure of 40cmH2O was achieved. After achieving the target pressure, this ventilatory regimen lasted 15 minutes. Positive end expiratory pressure and the inspired oxygen fraction were not modified.

OTHER

PSV10

Application of a ventilator hyperinflation intervention with Pressure Support Ventilation (PSV). The cycling off was set at 10% of peak inspiratory flow and the pressure support was increased until a peak pressure of 40cmH2O was achieved. After achieving the target pressure, this ventilatory regimen lasted 15 minutes. Positive end expiratory pressure and the inspired oxygen fraction were not modified.

OTHER

PSV25

Application of a ventilator hyperinflation intervention with Pressure Support Ventilation (PSV). The cycling off was set at 25% of peak inspiratory flow and the pressure support was increased until a peak pressure of 40cmH2O was achieved. After achieving the target pressure, this ventilatory regimen lasted 15 minutes. Positive end expiratory pressure and the inspired oxygen fraction were not modified.

All Listed Sponsors
collaborator

Universidade Federal do Rio de Janeiro

OTHER

lead

Centro Universitário Augusto Motta