EOS X-rays
Full length, orthogonal anteroposterior and lateral X-rays will be taken simultaneously in a standardised standing position, with arms folded anteriorly in 45 degrees . All radiographs will include C7 proximally and the femoral heads distally. 3D reconstruction of the spine can be performed. X-rays will be repeated after the brace is applied, and at intervals of no fewer than 6 months until the brace is weaned off, or if surgical intervention is required. Coronal, sagittal and axial parameters will be calculated from the reconstruction. 3D vertebral wedging will be calculated in the posterofrontal, sagittal and diagonal planes at the apex, 3 superior and 3 inferior vertebrae, as described by Scherrer et al. Changes in the pre- and post-bracing and follow-up parameters can be calculated.