61
Participants
Start Date
March 25, 2017
Primary Completion Date
January 25, 2018
Study Completion Date
January 30, 2018
Pulse pressure variation guided fluid therapy
Pulse pressure variation obtained from invasive blood pressure waveform
Traditional fluid therapy
4 ml/Kg/hr ringer solution plus rescue fluid bolus of 200 ml Ringer solution if Mean arterial pressure decreased by 20% with central venous pressure less than 4 mmHg.
Brain tumor excision
Brain tumor excision under general anesthesia
Cairo University, Cairo
Cairo University
OTHER