80
Participants
Start Date
November 1, 2018
Primary Completion Date
August 31, 2019
Study Completion Date
November 30, 2019
Pectoralis II block & catheter without Lidocaine dissection
B Braun Catheter Kit Contiplex with a 18 gauge needle will be used. After topicalization of the skin and sterilization using ultrasound guidance to facilitate performing insertion of the canula. Confirming the tip position will be done by ultrasonography while performing pectoralis type 2 block for cases undergoing simple mastectomy procedures
Pectoralis II block & catheter with Lidocaine dissection
B Braun Catheter Kit Contiplex with a 18 gauge needle will be used. After topicalization of the skin and sterilization using ultrasound guidance to facilitate performing insertion of the canula. 10 ml of lidocaine 1% will be injected for plan dissection to facilitate the procedure. Confirming the tip position will be done by ultrasonography while performing pectoralis type 2 block for cases undergoing simple mastectomy procedures
catheter insertion
catheter insertion after Lidocaine dissection
Kasr Alaini Hospitals, Cairo
Kasr El Aini Hospital
OTHER