54
Participants
Start Date
July 31, 2015
Primary Completion Date
October 1, 2016
Study Completion Date
December 1, 2016
Active tPCS
A current intensity of 2mA and a stimulation frequency range of 6-10 Hz will be used with a peri-aurical ear-clip electrode montage for 20 minutes.
Active tDCS
A current intensity of 2.0 mA will be used for 20 minutes. The electrodes that will be used will be standard sponge electrodes. The anode will be placed over left motor cortex. The cathode electrode will be placed over the contralateral supraorbitofrontal area.
Sham tPCS
Sham tPCS stimulation will consist of applying the same parameters as for active, but the corresponding device will be turned off after 30 seconds, as to simulate the initial sensation of the active current. A current intensity of 2mA and a stimulation frequency range of 6-10 Hz will still be used (only this will be turned off after 30 seconds using ramping) with a peri-aurical ear-clip electrode montage.
Sham tDCS
Sham tDCS stimulation will consist of applying the same parameters as for active, but the corresponding device will be turned off after 30 seconds, as to simulate the initial sensation of the active current. A current intensity of 2.0 mA will still be used (but turned off after 30 seconds using ramping). The electrodes that will be used will be same, standard sponge electrodes. The anode will be placed over the left motor cortex The cathode electrode will be placed over the contralateral supraorbitofrontal area.
Spaulding Rehabilitation Network Research Institute, Charlestown
Spaulding Rehabilitation Hospital
OTHER