Intensity Modulated Radiation Therapy
"We are using thermoluminescent dosimeter (TLD) to measure the mucosal dose adjacent to the dental fillings in a standard, non-filling optimized IMRT (intensity modulated radiotherapy treatment) plan that is normally delivered in the clinic. If the measured mucosal dose exceeds 35 Gy, we will generate a filling optimized IMRT plan to reduce it to \< 35 Gy. The new plan will be deemed acceptable and implemented only if it does not (1) compromise the tumor coverage, (2) increase the dose to either the remaining oral cavity or the spared parotid gland(s)."