Comparison of Biliary Forceps Biopsy and Brush Cytology

NACompletedINTERVENTIONAL
Enrollment

43

Participants

Timeline

Start Date

January 31, 2006

Primary Completion Date

July 31, 2009

Study Completion Date

July 31, 2009

Conditions
Cholangiocarcinoma
Interventions
DEVICE

double-balloon enteroscopy forceps biopsy

An endoscopic retrograde cholangiography (ERC) with a duodenoscope Olympus TFJ 160-R (Olympus Corp., Tokyo, Japan) and endoscopic sphincterotomy with an Olympus papillotome (Olympus) is performed under analgosedation . Then, the cannulation of the bile duct is performed by a pusher using a guidewire/guiding catheter. Subsequently, 2 histology samples are taken via a double-balloon enteroscopy (DBE) forceps (BF1725DF, Fujinon GmbH, Willich, Germany), which is placed under the guidance of the pusher.

DEVICE

Transpapillary brush cytology

An endoscopic retrograde cholangiography (ERC) with a duodenoscope Olympus TFJ 160-R (Olympus Corp., Tokyo, Japan) and endoscopic sphincterotomy with an Olympus papillotome (Olympus) is performed under analgosedation . The region of interest is then brushed five times in both directions to obtain cytology specimen.