Study of Sequentially Applied Repetitive Transcranial Magnetic Stimulation in Obsessive- Compulsive Disorders

NACompletedINTERVENTIONAL
Enrollment

21

Participants

Timeline

Start Date

February 28, 2007

Primary Completion Date

January 31, 2008

Study Completion Date

January 31, 2008

Conditions
Obsessive-compulsive Disorder
Interventions
DEVICE

repetitive transcranial magnetic stimulation (Magstim rapid magnetic stimulator)

"For the active group, rTMS over the right prefrontal cortex and the SMA was sequentially performed. The rTMS of the right dorsolateral prefrontal cortex was conducted at a point 5 cm anterior to the point at which the MT was determined, and it was administered at an intensity of 110% of the RMT, a frequency of 1 Hz, for 10 minutes, and with an inter-train interval of 2 minutes (1200 stimuli/d).~The vertex (Cz) was measured for each patient, and the SMA was defined at 15% of the distance between the inion and nasion anterior to Cz on the sagittal midline, according to the international 10-20 EEG system. The rTMS over the SMA was administered at an intensity of 100% of the RMT, a frequency of 1 Hz, for 10 minutes and with an inter-train interval of 2 minutes (1200 stimuli/d).~For the sham group, the sham stimulation was applied with the coil angled at 45° from the scalp using the same parameters as the active stimulation group over the same area."

Trial Locations (1)

120-752

Yonsei Univ. Health System Severance Hospital, Seoul

All Listed Sponsors
lead

Severance Hospital

OTHER

NCT00932204 - Study of Sequentially Applied Repetitive Transcranial Magnetic Stimulation in Obsessive- Compulsive Disorders | Biotech Hunter | Biotech Hunter