150
Participants
Start Date
June 30, 2025
Primary Completion Date
January 1, 2028
Study Completion Date
January 1, 2028
proprioceptive profile measurement
"Proprioceptive profile is measured by assessing static bipodal balance on a force platform. The patient is asked to stand motionless in bipodal support on a stable and then unstable floor, with vision masked by an eye mask. The investigators randomly apply a tendon vibration (80Hz) to the subjects' Achilles tendons or paravertebral muscles.~This vibration alters proprioceptive information in the vibrated zone, leading to a disturbance in postural balance and an increased displacement of the center of pressure, whose position is continuously calculated from the force platform's sensors.~Thus, depending on the amount of displacement of the center of pressure, the investigator calculates a proprioceptive weighting ratio (PWR) to deduce the weight assigned by the Central Nervous System to the various proprioceptive inputs during the postural task.~An PWR of 1 indicates 100% use of information from the ankle, while an PWR of 0 means 100% use of information from the hip."
RECRUITING
CHU Montpellier, Montpellier
University Hospital, Montpellier
OTHER