60
Participants
Start Date
February 1, 2025
Primary Completion Date
April 1, 2025
Study Completion Date
August 1, 2025
hair cortisol
To extract cortisol from the hair, the sample is carefully sectioned into segment lengths that will approximate the time period of interest (from the outermost part, if the hair is 3 cm long, the cortisol secreted proportionally by the individual in the last 3 months of life will be extracted). Then, an approximate average weight per sample of 150 mg will be selected. The samples will be individualised and placed in eppendorfs (one for each patient) and sprayed with scissors. After incubation in methanol for 36 hours, the supernatant portion is extracted, which already contains dissolved cortisol. This solution shall be evaporated to dryness, and then the pellet shall be reconstituted with phosphate (PBS). A commercial kit for the quantification of cortisol by immunoassay (ELISA Victor X5) shall be used. The ELISA kit for the detection of cortisol in saliva (ELISA Kits ' Cortisol ELISA Kits Human Cortisol Competitive ELISA Kit ,Invitrogen).
salivary cortisol
Three saliva samples will be collected from each subject, at 8:00, 15:00 and 23:00 hours. Before collecting the saliva they will be instructed to rinse their mouth with cold water, without brushing their teeth. They should also not eat or drink in the hour before the sample is taken. Approximately 1 ml of saliva, collected by direct expectoration into an ependymal tube, shall be obtained and the samples shall be stored for 24 hours at 4°C . Subsequently, samples shall be centrifuged at 2 500 rpm/10 min and the supernatant shall be stored at -20 °C until processing by ELISA kit as per the above protocol.
salivary Oxytocin
The treatment and collection of saliva as a biological sample shall be identical to the protocol described for the determination of cortisol. The determination of oxytocin shall be carried out by the use of ELISA kit for immunoassay (Oxytocin ELISA Kit (ab133050 ABCAM)
Bayley-III Child Development Assessment Scales
They are a set of three standardised assessment scales, which assess the cognitive, motor and language development of children aged 1 and 42 months. For our study, we will use only the motor scale, which is composed of two subscales, the gross motor scale and the fine motor scale. This motor scale is composed of 138 items (the gross motor scale is composed of 72 items and the fine motor scale of 66 items) which assess the degree of control of the body, the coordination of large muscle masses and the manipulative ability of hands and fingers. The total administration time of the motor area for 12-month-old children, as in the case of the sample, is between 15 and 20 minutes.
Strange Situation
The Strange Situation is a standardised observational procedure in which the child is exposed to two moments of separation from his/her attachment figure, two moments of reunion with the attachment figure and moments in which he/she interacts with an unknown person, specifically 8 episodes (lasting 3 minutes) in which the level of stress provoked in the child increases in intensity as the situation progresses. It is estimated to last around 20 minutes. It is assessed on a 7-point Likert-type scale, so that low scores indicate low frequency and intensity of the behaviour. These responses allow us to identify three types of attachment: secure attachment, insecure-avoidant attachment and insecure-ambivalent attachment. The strange situation only allows us to assess attachment in children between 1 and 2 years of age.
Parenting Stress Index (PSI)
It assesses the stress experienced in parenting through several subscales such as parental distress, dysfunctional parent-child interaction and whether the child is a difficult child based on how parents perceive their children's behaviour.
Perinatal Risk Inventory
"\- The Perinatal Risk Inventory is a measuring instrument that provides information on the neonatal situation prior to discharge and facilitates an estimate of the biological risk that the child may present from a very early age. The factors that are analysed in this inventory are evaluated with a score from 0 to 3 for each of the factors mentioned above, ranging from a minimum of 0 points to a maximum of 51. The levels of risk were determined as follows:~1. Low Neonatal Risk: 0 to 6 points.~2. Moderate Neonatal Risk: 7 to 9 points.~3. High Neonatal Risk: 10 or more points."
Neonatal Behavioural Assessment (NBAS)
is an assessment technique that provides a profile of scores that allows us to detect a possible alteration or pathology, but at the same time, within normal parameters, to detect both the potential or 'strong points' and the problems or 'weak points' of the newborn, as well as their peculiar ways of acting and reacting to environmental variables. Therefore, a profile of the child's behavioural characteristics is obtained, which can be considered as a first outline of the child's temperamental traits. It evaluates the behavioural repertoire of the newborn in 28 behavioural items that are assessed according to a 9-point scale. The scale also includes an assessment of neurological status in 18 reflex items, each with a 4-point rating. In the second edition of the NBAS a series of 7 supplementary items were added with the intention of better capturing the degree of fragility and the quality of behaviour of high-risk children.
Galvanic Response
Galvanic Response: has the function of measuring the galvanic response of the skin, also known as electrodermal activity (EDA). It is used to record the electrical behaviour of the skin, which varies according to the activity of the sweat glands. This measurement of electrodermal activity is essential for studying the activity of the autonomic nervous system, which controls involuntary body functions such as sweating and heart rate. It will be measured with the BIOPAC MP36R device.
electrocardiography (ECG)
"ECG is used as a monitoring target for various cardiovascular conditions. It will be measured with the BIOPAC MP36R device.~P, Q, R, S, T, U waves; QRS complex, PR interval and QT interval and PR segment and ST segment."
Breathing respiratory rate
The transducer is attached to a strap that is placed around the subject's chest, allowing chest movements to be detected during breathing. The strap ensures a secure and comfortable fit for the subject during the measurement process. This transducer is used in conjunction with other BIOPAC components to assess physiological responses. The data obtained from the transducer provides information on respiratory patterns and their relationship to other physiological measures. It will be measured with the BIOPAC MP36R device.
Universidad CEU Cardenal Herrera, plaza Reyes Catolico 19, 03204 Elche (alicante ), Elche
FUNDACIÓN SALUD INFANTIL
UNKNOWN
Cardenal Herrera University
OTHER