Evaluation of Implant Stability Changes in Sites Prepared with Different Osseodensification Techniques: a Prospective Observational Clinical Study

CompletedOBSERVATIONAL
Enrollment

12

Participants

Timeline

Start Date

February 15, 2024

Primary Completion Date

July 15, 2024

Study Completion Date

November 5, 2024

Conditions
EdentulousAlveolar Process Atrophy
Interventions
PROCEDURE

Implant site preparation with osteotomes and electrified mallet

"Under local anesthesia (mepivacaine HCL 2% with epinephrine1:100.000), a minimally invasive full-thickness flap was elevated to expose the alveolar crest.~A pilot osteotome (100-P) was used to easily perforate the cortical plate. Subsequently, osteotomes with gradually increasing diameters were employed until the final diameter of 3.2 mm was reached.~The sequence of osteotomes and their respective diameters were as follows:~1. Osteotome 100-P: At a height of 8.5 mm, the diameter was 2.2 mm;~2. Osteotome 160: At a height of 8.5 mm, the diameter was 2.8 mm;~3. Osteotome 200: At a height of 8.5 mm, the diameter was 3.2 mm. Implant (4.0x8.5 mm; Anyridge, Megagen, Gyeongbuk, South Korea) was positioned using a surgical motor.~A 3 mm high transepithelial abutment (OCTA, Megagen, Gyeongbuk, South Korea) was connected to it using a torque wrench and it was tightened to 30 Ncm.~Single sutures in monofilament synthetic polypropylene 4.0 were performed to close flaps around the abutment."

PROCEDURE

Implant site preparation with osseodensification drills

"Under local anesthesia (mepivacaine HCL 2% with epinephrine1:100.000), a minimally invasive full-thickness flap was elevated to expose the alveolar crest.~The implant site preparation was realized using osseodensification burs at a rotation speed of 1200 rpm. The osseodensification burs sequence was as follows:~1. Initial pilot hole (rotated clockwise);~2. WT1828 bur (rotated counterclockwise),~3. WT2838 bur (rotated counterclockwise). Implant (4.0x8.5 mm; Anyridge, Megagen, Gyeongbuk, South Korea) was positioned using a surgical motor.~A 3 mm high transepithelial abutment (OCTA, Megagen, Gyeongbuk, South Korea) was connected to it using a torque wrench and it was tightened to 30 Ncm.~Single sutures in monofilament synthetic polypropylene 4.0 were performed to close flaps around the abutment."

Trial Locations (1)

43100

Piezosurgery Academy, Parma

All Listed Sponsors
collaborator

University of Trieste

OTHER

lead

International Piezosurgery Academy

OTHER

NCT06679894 - Evaluation of Implant Stability Changes in Sites Prepared with Different Osseodensification Techniques: a Prospective Observational Clinical Study | Biotech Hunter | Biotech Hunter