Accuracy of Intraoral Photogrammetry Scanner in Complete Arch Digital Implant Impression

PHASE1CompletedINTERVENTIONAL
Enrollment

60

Participants

Timeline

Start Date

June 20, 2024

Primary Completion Date

August 10, 2024

Study Completion Date

August 20, 2024

Conditions
Dental Implant
Interventions
PROCEDURE

Digital scanning

. For each patient three digital files will be obtained: One reference scan, one conventional IOS scan, and one IPS scan. All the STL files will be imported to dental CAD software, and scan bodies will be converted to implant multi-unit ti-base using a digital library. The updated STL files will be imported to inspection software Mimics for trueness assessments. The three-dimensional discrepancy between 2 STL files will be evaluated in terms of linear and angular deviation. A central point \& central axis of the virtual MUA ti-base was used for deviation measurements. Linear deviations will be assessed for each MUA tibase on the three-space axis (X longitudinal, Y lateral, and Z vertical) using the center of the ti-base heads for the deviation measurement. Angular deviations were assessed as the angles formed by the two lines passing perpendicularly through the centers of the test image and the reference image of each ti-base.

PROCEDURE

Two digital impressions will be recorded, one with a conventional intra-oral scanner and another one with an intra-oral photogrammetry scanner.

. For each patient three digital files will be obtained: One reference scan, one conventional IOS scan, and one IPS scan. All the STL files will be imported to dental CAD software, and scan bodies will be converted to implant multi-unit ti-base using a digital library. The updated STL files will be imported to inspection software Mimics for trueness assessments. The three-dimensional discrepancy between 2 STL files will be evaluated in terms of linear and angular deviation. A central point \& central axis of the virtual MUA ti-base was used for deviation measurements. Linear deviations will be assessed for each MUA tibase on the three-space axis (X longitudinal, Y lateral, and Z vertical) using the center of the ti-base heads for the deviation measurement. Angular deviations were assessed as the angles formed by the two lines passing perpendicularly through the centers of the test image and the reference image of each ti-base.

Trial Locations (2)

11566

Faculty of Dentistry Ain Shams University, Cairo

15666

Faculty of Dentistry Ain Shams University, Cairo

All Listed Sponsors
collaborator

Assiut University

OTHER

lead

Ain Shams University

OTHER

NCT06599294 - Accuracy of Intraoral Photogrammetry Scanner in Complete Arch Digital Implant Impression | Biotech Hunter | Biotech Hunter