40
Participants
Start Date
October 1, 2023
Primary Completion Date
December 31, 2024
Study Completion Date
June 30, 2025
Dual chamber Medtronic pacemaker implantation.
"All patients will undergo a dual chamber Medtronic pacemaker implantation meeting approved indications for pacemaker implantation per Centers for Medicare \& Medicaid Services (CMS) guidelines.~Pacemaker Model: Azure XT W1DR01. Right ventricular lead model: Medtronic 3830."
DDD-50 pacing program
This device programming attempts to increase the amount of ventricular pacing via the Medtronic 3830 lead. Since the enrolled patients have a prolonged PR interval, this programming attempts to synchronic atrial and ventricular contractions.
AAI-DDD 50 pacing program
This device programming attempts to encourage native conduction and minimize ventricular pacing via the Medtronic 3830 lead. This programming attempts to minimize ventricular pacing, which has been associated with worse outcomes by causing ventricular dyssynchrony between the left and right ventricles.
RECRUITING
Ascension Saint Thomas Midtown, Nashville
Lead Sponsor
Collaborators (1)
Medtronic
INDUSTRY
Ascension Health
INDUSTRY