50
Participants
Start Date
November 15, 2023
Primary Completion Date
January 15, 2024
Study Completion Date
January 30, 2024
Transcutaneous Auricular Vagus Nerve Stimulation (taVNS)
Current will be applied bilaterally from the tragus and turbinate parts of the ear with the VagustimTM device. The current frequency to be used in modulation mode is 10 Hz, and the pulse width is 300 μs (In modulation mode, the pulse rate and width are automatically changed in a loop pattern. The pulse width is reduced by 50% from its original setting in 0.5 seconds; then, the pulse rate is changed in 0.5 seconds, reduced by 50% from the original setting. Total cycle time is 1 second.). The current intensity will be applied for 5 minutes, keeping the current constant where the participant feels comfortable.
Sham Transcutaneous Auricular Vagus Nerve Stimulation (taVNS)
For 5 minutes, sham applications will be applied using a current-free headset specifically designed for this purpose. Participants will observe the device's functionality, but it will not supply any current.
Zeynep Yıldız Kızkın, Artvin
Artvin Coruh University
OTHER