Observation Study for Prediction of Allograft Survival and Impact of Imaging in Kidney Transplant Recipients.

RecruitingOBSERVATIONAL
Enrollment

1,000

Participants

Timeline

Start Date

January 1, 2007

Primary Completion Date

August 31, 2024

Study Completion Date

August 31, 2024

Conditions
Kidney Transplantation
Interventions
DIAGNOSTIC_TEST

PET/CT imaging

The PET/CT procedure was performed using cross-calibrated Philips Gemini TF Big Bore or TF 16 PET/CT systems (Philips Medical Systems, Cleveland, OH) at 201 18 minutes following intravenous injection of a mean dose of 3.2 0.2 MBq/kg of body weight of 18 F-FDG. A low-dose helical CT (5-mm slice thickness, 120-kV tube voltage, and 40-mAs tube current-time product) centered to the renal transplant was performed, followed by PET scanning with two bed positions, each lasting 240 seconds. Images were reconstructed using iterative list mode time-of-flight algorithms. Corrections for attenuation, dead time and random and scatter events were applied.

Trial Locations (1)

4000

RECRUITING

Centre Hospitalier Universitaire de Liège, Liège

All Listed Sponsors
lead

University of Liege

OTHER