Gait Examination in Patients With Hemophilia in Austria

CompletedOBSERVATIONAL
Enrollment

42

Participants

Timeline

Start Date

July 2, 2018

Primary Completion Date

July 1, 2019

Study Completion Date

July 1, 2019

Conditions
Hemophilia
Interventions
DIAGNOSTIC_TEST

3-d gait examination (level walking)

"Instrumented 3d-gait-analysis will be carried out in the movement lab of the FH (Fachhochschule; University of Applied Sciences) Campus Wien - University of Applied Sciences. The system used is a 10 camera T40S Vicon system with two floor-mounted AMTI OR6/7-2000 force plates. For assessing gait the Plug-in-Gait Lower Body Model with 14 mm retroreflective skin-mounted markers is implemented in the capturing software Vicon Nexus 2.2. The specific parameters will be extracted from the reporting software Vicon Polygon 4.2.~Markers will be placed by one experienced examiner. Subjects will be instructed to walk barefoot on a 10 meters walkway at self-paced walking speed until five right and five left valid first force plate strikes are captured."

DIAGNOSTIC_TEST

Anthropometrics and body composition assessment

Body height will be measured with the stadiometer Seca 213 to the next 0.1cm. Body size and weight will be measured without shoes and outerwear. A correction of 1 kg will be subtracted for clothing. Body weight and body composition will be assessed with the medical body composition analyzer Seca mBCA 515 based on bioelectric impedance analysis.

DIAGNOSTIC_TEST

Biomarkers

"Blood will be collected into Vacuette serum-separating tubes and will be kept at room temperature for 30 min. Samples will be centrifuged at 1500g for 10 min and serum aliquots will be stored at 80 C until use. Urine samples will be collected into Vacuette tubes containing no additive from non-fasted individuals between 8:00 and 12:00 a.m. Urine samples will be kept at 4 °C for a maximum of 8 h, and then aliquoted and stored at 80 °C.~All biomarkers (except vitamin D and CRP) will be measured in duplicates using standard enzyme-linked immunosorbent assay (ELISA) kits. Serum samples will be assessed for the level of sCOMP, sC1,2C, and sCS846, IL-6, IL-1, sTNFR1 and sTNFR2. Vitamin D and CRP will be measured using automated immunoassay. In urine samples uCTX-II will be determined and these levels will be corrected for creatinine levels (Jaffé method, in-house validated method)."

DIAGNOSTIC_TEST

Clinical examination

Hemophilia joint health score (HJHS) will be assessed. Height will be measured with a stadiometer (SECA 213), weight with a medical scale (Marsden M-420) and leg length according to the Plug-in-Gait protocol with a measuring tape from the Anterior Spina Iliaca Superior to the distal aspect of the Medial Malleolus. Further anthropometrical parameters taken will be knee distance and malleoli distance by using a caliper. Gait relevant passive joint ROM of the knee, hip and ankle will be assessed by means of a handheld goniometer. The flexibility of hamstring muscles will be expressed as Popliteal Angle measured with a goniometer with the subjects supine and the hip in 90° flexion.

DIAGNOSTIC_TEST

Habitual physical activity tracking (accelerometer based)

Participants will be instructed to wear an Actigraph wGT3X-BT tri-axial accelerometer permanently over a period of seven consecutive days with an elastic band on right hand sided hip. Data will be process with software ActiLife version 6.13. Cut-offs of at least 10 hours daily wear-time and a minimum of three valid weekdays and one valid weekend day will be applied for data cleaning. Count sampling epoch will be set at one minute. The so called Freedson Adult VM2 Cut-Offs will be applied to categorize physical activity intensities. The so called Freedson VM3 Combination will be applied for the estimation of activity energy expenditure.

Trial Locations (1)

1100

FH Campus Wien - University of Applied Sciences, Vienna

Sponsors

Collaborators (1)

All Listed Sponsors
collaborator

Medical University of Vienna

OTHER

collaborator

Shire

INDUSTRY

lead

FH Campus Wien, University of Applied Sciences

OTHER