Use of Indirect Calorimetry in Obesity

CompletedOBSERVATIONAL
Enrollment

355

Participants

Timeline

Start Date

April 1, 2012

Primary Completion Date

October 31, 2016

Study Completion Date

October 31, 2016

Conditions
Metabolism DisorderOverweight and Obesity
Interventions
DIAGNOSTIC_TEST

Indirect calorimetry

"Indirect calorimetry will be performed by using an open-circuit calorimeter (Sensor Medics, Italy). Indirect calorimetry is the reference method for energy expenditure determination. A canopy hood covered the patient's head and expired air is extracted by a pump to be analyzed by metabolic cart sensors; flow rate is directly measured with a digital turbine flowmeter. After an overnight fast, patients will asked to lay supine in complete physical rest, not sleeping or talking for approximately 20-25 minutes, at a room temperature ranged between 22 and 24°C. The mean REE for each participant considers the last 15-20 minutes of measurements corresponding to steady state.~Software of calorimeter will be set for minute-by-minute reading report of VO2 (Oxygen flow) and VCO2 (Carbon dioxide flow) measurement.~Parameters obtained by Indirect Calorimetry will be the Resting Energy Expenditure and the Respiratory Quotient (RQ)"

Trial Locations (1)

20097

San Donato Hospital, San Donato Milanese

All Listed Sponsors
lead

Ospedale San Donato

OTHER